Tariff Period | Technology | No. of Years | |
Wind | Not available | ||
Mini-hydel | -- | ||
Bagasse based co-generation. | -- | ||
Biomass based on Rankine cycle (water cooled condenser). | -- | ||
Solar rooftop and small PV power plants, grid-connected megawatt scale solar power plants. | 25 | ||
MSW to Energy | -- | ||
| |||
Control Period | Technology | Period | |
Wind | 1st April 2018 to 31st March 2019 | ||
Solar rooftop and small PV power plants, grid-connected megawatt scale solar power plants. | |||
Mini-hydel, bagasse based co-generation, biomass based on Rankine cycle (water cooled condenser). | 1st April 2018 to 31st March 2021 | ||
MSW to Energy | 19th September 2016 to 31st March 2019 | ||
| |||
Useful Life of a Plant | Technology | No. of Years | |
Wind, solar rooftop and small PV power plants, grid-connected megawatt scale solar power plants. | 25 | ||
Mini-hydel | 35 | ||
Bagasse based co-generation, biomass based on Rankine cycle (water cooled condenser), MSW to Energy. | 20 | ||
| |||
Technology-wise Gross Tariff | Technology | Gross Tariff (in Rs./kWh) | |
Wind | 3.45 | ||
Mini-hydel | 3.95 | ||
Bagasse based co-generation. | Fixed cost | 1.77 | |
Variable cost (FY 2018-19) | 1.82 | ||
Variable cost (FY 2019-20) | 1.92 | ||
Variable cost (FY 2020-21) | 2.03 | ||
Biomass based on Rankine cycle (water cooled condenser). | Fixed cost | 2.19 | |
Variable cost (FY 2018-19) | 3.36 | ||
Variable cost (FY 2019-20) | 3.55 | ||
Variable cost (FY 2020-21) | 3.76 | ||
Biomass based on Rankine cycle (air cooled condenser). | Fixed cost | 2.07 | |
Variable cost (FY 2018-19) | 3.28 | ||
Variable cost (FY 2019-20) | 3.47 | ||
Variable cost (FY 2020-21) | 3.66 | ||
Megawatt scale solar PV projects below 5 MW capacity. | 3.05 | ||
Solar rooftop PV projects of 1 MW and below. | Without capital subsidy | 3.56 | |
With capital subsidy | 2.67 | ||
MSW to Energy | 7.08 | ||
Capital Cost | Technology | Capital Cost | |
Wind (Rs. lakh/MW) | 575.00 | ||
Mini-hydel (Rs. lakh/MW) | 633.00 | ||
Bagasse based co-generation (Rs. lakh/MW). | 470.00 | ||
Biomass based on Rankine cycle (water cooled condenser) (Rs. lakh/MW). | 576.00 | ||
Biomass based on Rankine cycle (air cooled condenser) (Rs. lakh/MW). | 586.00 | ||
Solar rooftop and small PV power plants (Rs./kW). | 40000.00 | ||
Grid-connected megawatt-scale solar PV plants (Rs. lakh/MW). | 350.00 | ||
MSW to Energy (Rs. lakh/MW). | 1700.00 | ||
| |||
Operation and Maintenance (O&M) Expenses | Technology | O&M Cost for the FY 2018-19 | |
Wind (Rs. lakh/MW) | 10.00 | ||
Mini-hydel (Rs. lakh/MW) | 14.66 | ||
Bagasse based co-generation (Rs. lakh/MW). | 14.10 | ||
Biomass based on Rankine cycle (water cooled condenser) (Rs. lakh/MW). | 28.80 | ||
Biomass based on Rankine cycle (air cooled condenser) (Rs. lakh/MW). | 23.44 | ||
Solar rooftop and small PV power plants (Rs. Lakh/kW). | 0.006 | ||
Grid-connected megawatt-scale solar PV plants (Rs. lakh/MW) | 4.50 | ||
MSW to Energy (% of capital cost) | 6% | ||
An annual escalation at the rate of 5.72% shall be considered. | |||
Capacity Utilization Factor (CUF) | Technology | CUF (%) | |
Wind | 29 | ||
Mini-hydel | 30 | ||
Bagasse based co-generation. | 60 | ||
Biomass based on Rankine cycle (water cooled condenser). | 75 | ||
Biomass based on Rankine cycle (air cooled condenser). | 75 | ||
Solar rooftop and small PV power plants. | 19 | ||
Grid-connected megawatt scale solar PV plants. | 19 | ||
MSW to Energy | 65 (1st year) 75 (balance useful life) | ||
| |||
Auxiliary Consumption | Technology | Aux. Con. (%) | |
Wind | 0.50 | ||
Mini-hydel | 1.00 | ||
Bagasse based co-generation. | 8.50 | ||
Biomass based on Rankine cycle (water cooled condenser). | 10.00 | ||
Biomass based on Rankine cycle (air cooled condenser). | 10.00 | ||
Solar rooftop and small PV power plants. | 0.00 | ||
Grid-connected megawatt scale solar PV plants. | 0.25 | ||
MSW to Energy | 12.00 | ||
| |||
Interest Rate on Loans | Technology | Rate of Interest (%) | |
Wind, solar rooftop and small PV power plants, grid-connected megawatt scale solar PV plants. | 10.00 | ||
Mini-hydel, bagasse based co-generation, biomass based on Rankine cycle (water cooled condenser), biomass based on Rankine cycle (air cooled condenser). | 10.50 | ||
MSW to Energy | 12.00 | ||
| |||
Depreciation |
| ||
Return on Equity |
| ||
Interest on Working Capital | Technology | Rate of Interest (%) | |
Wind, solar rooftop and small PV power plants, grid-connected megawatt scale solar PV plants. | 11.00 | ||
Mini-hydel, bagasse based co-generation, biomass based on Rankine cycle (water cooled condenser), biomass based on Rankine cycle (air cooled condenser). | 11.50 | ||
MSW to Energy | 12.50 | ||
| |||
Specific Fuel Consumption | Technology | Value (kg/kWh) | |
Bagasse based co-generation plant. | 1.60 | ||
Biomass based on Rankine cycle (water cooled condenser). | 1.21 | ||
Biomass based on Rankine cycle (air cooled condenser). | 1.18 | ||
| |||
Fuel Cost | Technology | Cost (Rs./MT) FY 2018-19 | |
Bagasse based co-generation plant | 1,039.00 | ||
Biomass based on Rankine cycle (water cooled condenser). | 2,500.00 | ||
Biomass based on Rankine cycle (air cooled condenser). | 2,500.00 | ||
|
OTHER PROVISIONS |
Tariff structure and design | Generic, single part, levelised tariff. |
Merit Order Despatch principle | Mini-hydel, wind. |
Subsidy or/and incentives by government | Not available |
Rebate | Not available |
Late payment surcharge | Not available |
Links | http://www.karnataka.gov.in/kerc/Pages/Generic%20Tariff%20Orders.aspx |
References | http://www.karnataka.gov.in/kerc/Documents/RE%20Tariff%20Order%202018.pdf |
About Portal
'All About Renewables' aims to bring about a change in the way we 'look and search' for data on renewables today, by providing access to the latest developments in the renewable energy sector (specifically renewable electricity), along with cross-linkages to the conventional energy sector, all on one single platform... Read More
About
Useful Links
Contact
Plot No.44, Hindustan Estates,
Kalyani Nagar, Pune 411 006, India
+91 20 26613855
+91 20 26613832